Lowest allowable CFM without Make up Air, Commercial Kitchen

$10-75 USD

Terminado
Publicado hace más de 5 años

$10-75 USD

Pagado a la entrega
Im in the process of opening a bar/tavern in Oregon. Im doing a ventless/hoodless. Building inspector has told me that even if I get rid of cooking equipment and have just my low-temp undercounter dishwasher (which aren't suppose to require it as they don't produce more steam than hot water out of faucet) I will be required to put in a minimum 50 CFM fan. I want to know what the lowest amount of CFM's of exhaust you can have before make up air is required. The math from mechanical code stated .70 CFM per square foot and my kitchen is 100 square feet approximately. My original plan was to have the undercounter dishwasher and 2 pieced of ventless equipment, which are also not suppose to require heat exhaust as they have them built into the equipment, and the math had something about 100 CFM per piece of equipment. I need someone to tell me what the lowest allowable amount of CFMs is before make up air is required to be installed. If its less than 400 I need an engineer to do the math and provide a stamp so that I can submit that to the building inspector and satisfy his need for it. I want to put in a fan that is the lowest allowable amount to help allow me to put the most pieces of equipment I can which sounds like it may only be 2 or 3. Exhaust duct will have one to two elbows and only need to exhaust about 10-15 feet out the side wall of building. I don't know much about this stuff and any help that can get me going is appreciated.
ID del proyecto: 17846704

Información sobre el proyecto

1 propuesta
Proyecto remoto
Activo hace 6 años

¿Buscas ganar dinero?

Beneficios de presentar ofertas en Freelancer

Fija tu plazo y presupuesto
Cobra por tu trabajo
Describe tu propuesta
Es gratis registrarse y presentar ofertas en los trabajos
Adjudicado a:
Avatar del usuario
i am a mechanical engineer and have done a course work on HVAC, also i have done a project that required the HVAC system designed for a 2 floors building. i understand the need of this project since the fresh air requirement in the kitchen is one of the important factor in kitchen design. I can help you in estimating this ventilation requirement with a very powerful tool used in HVAC industry that is named "HAP" (hourly analysis program). I have very good command in using this software also I can use a duct sizing software to help u estimate the ducting in your kitchen. As a final product i will provide you with the fan to be installed for required CFM and any recommendations for a effective small system installation. I assure you of very timely project delivery
$50 USD en 5 días
0,0 (0 comentarios)
0,0
0,0

Sobre este cliente

Bandera de UNITED STATES
Seaside, United States
0,0
0
Forma de pago verificada
Miembro desde sept 26, 2018

Verificación del cliente

¡Gracias! Te hemos enviado un enlace para reclamar tu crédito gratuito.
Algo salió mal al enviar tu correo electrónico. Por favor, intenta de nuevo.
Usuarios registrados Total de empleos publicados
Freelancer ® is a registered Trademark of Freelancer Technology Pty Limited (ACN 142 189 759)
Copyright © 2024 Freelancer Technology Pty Limited (ACN 142 189 759)
Cargando visualización previa
Permiso concedido para Geolocalización.
Tu sesión de acceso ha expirado y has sido desconectado. Por favor, inica sesión nuevamente.